Technical characteristics
Standard equipment:
- Hermetic compressor *
- Semi-hermetic compressor *
- Anti-vibration compressor brackets
- Vibration-cushioned suction and discharge piping of the compressor
- Crankcase resistance
- Air condensation
- Sound-absorbing body coating
- Galvanized powder coated sheet steel body
- Evaporator body of aluminium-magnesium alloy
- Evaporator of copper pipes and aluminium fins
- Condenser of copper pipes and aluminium fins
- Automatic restarting low pressure switch
- Automatic restarting high pressure switch
- Axial fan
- Safety valve *
- Condenser fans protection
- Thermic compressor protection
- Thermic compressor protection with motor protection *
- Condensation control pressure switch
- Thermostatic expansion valve with external equalization
- Dehydrator filter
- Liquid gas solenoid valve
- Liquid receiver
- Sight glass
- Suction pipe stop cock
- Liquid gas pipe stop cock
- Automatic electric defrosting
- Compressor stop in idling
- High and low pressure ¼” pipe plugs
- Condensation outlet resistor (only for low temperature models)
- Thermic magnetic switch
- Cold room ceiling light
- Ambient temperature probe
- Defrosting end temperature probe
- Condensation control temperature probe
- Connecting cable for door micro switch to turn off the system and to turn on the light at door opening
- Free relay for transfer alarm signals
Remote control with:
- Transformer
- Digital display with temperature indicator at one decimal
- On/Off switch
- Cold room light switch
- Running state display: cold – defrosting – evaporator fans – alarm status
- Programming keys
- Alarm display
- Manual defrosting key
- High temperature alarm
- Low temperature alarm
- High temperature alarm dirty condenser
- Low temperature alarm condenser
- Open door alarm
- High pressure alarm
- Low pressure alarm
- Defrosting end alarm because of time-out
- Alarm ambient temperature probe defect
- Alarm defrosting end temperature probe defect
- Alarm condensation control temperature probe defect
- Timer emergency running in case of these events:- Ambient temperature probe defect- Defrosting end temperature probe defect
– Condensation control temperature probe defect
– Cold room door open (if there is door micro switch) - Installation possibility of a second remote control as slave
- Pre-set connection for Frigotel supervision
Optional:
- Door micro switch
- Water condensation with liquid receiver. Pressure control valve. Pipe connection ½”
- Different voltage
- Tropicalised version
- Condenser fan speed regulator
- Pre-heated switchboard
- Voltage display for machine stop in case of incorrect power supply
- Long distance option for the remote control at distances longer than 15 m
- Acoustic siren with flashing to indicate the alarm state
- Switchboard for the management of two machines in the same cold room
- Another remote control to use as slave
- Electronic module for the connection to Frigotel supervision system
- Evaporator with cataphoretically painting
- Condenser with cataphoretically painting
- Acoustical soundproofed version
* depending on model
Destined use
Cibin’s refrigerating equipment is classed as food and agricultural machinery (MACHINES DIRECTIVE 2006/42/EC), destined for the treatment of food products.
The machine is designed for the conservation of foods and/or “fresh” products at temperatures indicated in annexes.
It has been designed to work in ambient temperatures from 0°C a +43°C (class T).
It has been designed to maintain a set temperature in a refrigerated cold room suitable for such uses.
The machine is not designed for use in cold rooms situated outside.
The machine is not designed for installation and use in an environment where there is risk of explosion.
Any use other than that permitted shall be considered improper, and in this case the Manufacturer will decline all liability.
The machine is not designed for the conservation of products, which produce corrosive substances.
Models
R404A – R507A
R452A
TN – R404A – R507A – R452A – 50 Hz
BT – R404A – R507A – R452A – 50 Hz
TN – R404A – R507A – R452A – Water-condensed units
BT – R404A – R507A – R452A – Water-condensed units
* Max ambient temperature: + 43°C
Ta: Ambient temperature
Tc: Cold room temperature
Refrigerant piping
Modello | Liquid piping | Suction piping |
---|---|---|
04123 N | Ø 6 mm – 1/4″ | Ø 10 mm – 3/8″ |
06125 N | Ø 6 mm – 1/4″ | Ø 10 mm – 3/8″ |
07125 N | Ø 10 mm – 3/8″ | Ø 12 mm – 1/2″ |
09125 N | Ø 10 mm – 3/8″ | Ø 12 mm – 1/2″ |
11225 N | Ø 10 mm – 3/8″ | Ø 12 mm – 1/2″ |
13225 N | Ø 10 mm – 3/8″ | Ø 12 mm – 1/2″ |
15225 N | Ø 10 mm – 3/8″ | Ø 12 mm – 1/2″ |
12125 B | Ø 10 mm – 3/8″ | Ø 12 mm – 1/2″ |
17125 B | Ø 10 mm – 3/8″ | Ø 12 mm – 1/2″ |
19325 N | Ø 10 mm – 3/8″ | Ø 16 mm – 5/8″ |
24325 N | Ø 10 mm – 3/8″ | Ø 16 mm – 5/8″ |
19225 B | Ø 10 mm – 3/8″ | Ø 16 mm – 5/8″ |
24225 B | Ø 10 mm – 3/8″ | Ø 16 mm – 5/8″ |
32325 B | Ø 10 mm – 3/8″ | Ø 16 mm – 5/8″ |
35325 B | Ø 10 mm – 3/8″ | Ø 16 mm – 5/8″ |
30235 N | Ø 12 mm – 1/2″ | Ø 18 mm – 3/4″ |
35235 N | Ø 12 mm – 1/2″ | Ø 18 mm – 3/4″ |
45235 B | Ø 12 mm – 1/2″ | Ø 18 mm – 3/4″ |
40235 SB | Ø 12 mm – 1/2″ | Ø 18 mm – 3/4″ |
50235 B | Ø 12 mm – 1/2″ | Ø 18 mm – 3/4″ |
30240 N | Ø 12 mm – 1/2″ | Ø 22 mm – 7/8″ |
75240 N | Ø 12 mm – 1/2″ | Ø 28 mm – 1 1/8″ |
40240 N | Ø 16 mm – 5/8″ | Ø 28 mm – 1 1/8″ |
50240 N | Ø 16 mm – 5/8″ | Ø 28 mm – 1 1/8″ |
100240 B | Ø 16 mm – 5/8″ | Ø 28 mm – 1 1/8″ |
150240 B | Ø 16 mm – 5/8″ | Ø 28 mm – 1 1/8″ |
Maximum distance: 15 m. For greater distances please contact the technical office.
Connection cables
Modello | C1 | C2 | C3 | C4 | C5 |
---|---|---|---|---|---|
mm2 | mm2 | mm2 | mm2 | mm2 | |
04123 N | 3 x 1.5 | 7 x 1.5 | 3 x 1* | 2 x 1* | 3 x 1* |
06125 N | 3 x 1.5 | 7 x 1.5 | 3 x 1* | 2 x 1* | 3 x 1* |
07125 N | 3 x 1.5 | 7 x 1.5 | 3 x 1* | 2 x 1* | 3 x 1* |
09125 N | 3 x 2.5 | 7 x 1.5 | 3 x 1* | 2 x 1* | 3 x 1* |
11225 N | 3 x 1.5 | 7 x 1.5 | 3 x 1* | 2 x 1* | 3 x 1* |
13225 N | 5 x 1.5 | 7 x 1.5 | 3 x 1* | 2 x 1* | 3 x 1* |
15225 N | 5 x 2.5 | 7 x 1.5 | 3 x 1* | 2 x 1* | 3 x 1* |
19325 N | 5 x 2.5 | 10 x 1.5 | 3 x 1* | 2 x 1* | 3 x 1* |
24325 N | 5 x 2.5 | 10 x 1.5 | 3 x 1* | 2 x 1* | 3 x 1* |
30235 N | 5 x 2.5 | 10 x 1.5 | 3 x 1* | 2 x 1* | 3 x 1* |
35235 N | 5 x 2.5 | 10 x 1.5 | 3 x 1* | 2 x 1* | 3 x 1* |
30340 SN | 5 x 4 | 5×1.5 + 5×4 | 3 x 1* | 2 x 1* | 3 x 1* |
40240 SN | 5 x 4 | 5×1.5 + 5×4 | 3 x 1* | 2 x 1* | 3 x 1* |
50240 SN | 5 x 6 | 5×1.5 + 5×4 | 3 x 1* | 2 x 1* | 3 x 1* |
12125 B | 3 x 1.5 | 7 x 1.5 | 3 x 1* | 2 x 1* | 3 x 1* |
17125 B | 3 x 1.5 | 7 x 1.5 | 3 x 1* | 2 x 1* | 3 x 1* |
19225 B | 5 x 1.5 | 7 x 1.5 | 3 x 1* | 2 x 1* | 3 x 1* |
24225 B | 5 x 1.5 | 7 x 1.5 | 3 x 1* | 2 x 1* | 3 x 1* |
32325 B | 5 x 2.5 | 10 x 1.5 | 3 x 1* | 2 x 1* | 3 x 1* |
35325 B | 5 x 2.5 | 10 x 1.5 | 3 x 1* | 2 x 1* | 3 x 1* |
45235 SB | 5 x 4 | 10 x 1.5 | 3 x 1* | 2 x 1* | 3 x 1* |
50235 SB | 5 x 4 | 10 x 1.5 | 3 x 1* | 2 x 1* | 3 x 1* |
C1 Power supply cable to condensing unit
C2 Connection cable between evaporator and condensing unit
C3 Probe connection cable between evaporator and condensing unit
C4 Door switch connection cable to condensing unit
C5 Connection cable to the remote keyboard control panel
*Shielded